FOR ENGINEERS AND DESIGNERS

Passive fire protection for steel structures

Technical support from steel section assessment through application and documentation.

  1. Assessment of the section factor Hp/A and the critical steel temperature.
  2. Selection of a certified Jotun intumescent coating system and determination of the required dry film thickness (DFT) for each section.
  3. Application, thickness checks and project documentation.

R30, R60, R90 or R120 requirements are assessed against the project design and the scope of application of the system.

Send drawings or a steel section schedule ↗
Architectural illustration of a steel arch bridge
Architectural illustration of a steel bridge

Intumescent Coatings for Structural Steel

Technical Support for Structural Engineers

Intumescent coatings are an advanced passive fire protection solution for steel structures where a specific fire resistance rating is required without increasing the section size or compromising the architectural appearance of the steelwork.

They are commonly applied to structural steel columns, beams, trusses, frames, and exposed steel elements in commercial, industrial, and public buildings.

Key Parameters for Fire Protection Design

The selection of the appropriate intumescent coating system and the required dry film thickness is based on:

Design and Specification Support

The performance of intumescent coatings for structural steel is typically assessed in accordance with EN 13381-8 and supported by certified testing, technical data sheets, and declarations of performance.

A properly specified system ensures that the steel structure maintains its load-bearing capacity for the required duration during a fire event.

Our Services for Structural Engineers

BAUFORM provides comprehensive technical support, including:

Why Intumescent Coatings Matter

Intumescent coatings are not simply decorative paints. They are engineered fire protection systems that must be selected and applied according to the structural design requirements, fire resistance criteria, and the characteristics of each steel member.

When exposed to fire, the coating expands and forms an insulating char layer that delays the temperature rise of the steel, helping maintain the structural integrity of the building.

Typical Applications

Contact Us

Send us your structural drawings, steel schedules, or fire resistance requirements, and our technical team will provide a tailored passive fire protection solution for your project.