FOR ENGINEERS AND DESIGNERS
Passive fire protection for steel structures
Technical support from steel section assessment through application and documentation.
- Assessment of the section factor Hp/A and the critical steel temperature.
- Selection of a certified Jotun intumescent coating system and determination of the required dry film thickness (DFT) for each section.
- Application, thickness checks and project documentation.
R30, R60, R90 or R120 requirements are assessed against the project design and the scope of application of the system.
Send drawings or a steel section schedule ↗
Intumescent Coatings for Structural Steel
Technical Support for Structural Engineers
Intumescent coatings are an advanced passive fire protection solution for steel structures where a specific fire resistance rating is required without increasing the section size or compromising the architectural appearance of the steelwork.
They are commonly applied to structural steel columns, beams, trusses, frames, and exposed steel elements in commercial, industrial, and public buildings.
Key Parameters for Fire Protection Design
The selection of the appropriate intumescent coating system and the required dry film thickness is based on:
- Required fire resistance period (R30, R60, R90, R120, etc.)
- Steel section type and dimensions
- Section factor (Hp/A or U/A)
- Critical steel temperature
- Beam or column classification
- Open or hollow steel sections
- Internal or external service environment
- Compatible primer and topcoat system
- Project-specific fire engineering requirements
Design and Specification Support
The performance of intumescent coatings for structural steel is typically assessed in accordance with EN 13381-8 and supported by certified testing, technical data sheets, and declarations of performance.
A properly specified system ensures that the steel structure maintains its load-bearing capacity for the required duration during a fire event.
Our Services for Structural Engineers
BAUFORM provides comprehensive technical support, including:
- Intumescent coating system selection
- Fire resistance calculations for steel members
- Determination of required dry film thicknesses
- Specification of primers, intumescent coatings, and finishing coats
- Professional application by trained personnel
- Dry film thickness measurements and quality control
- Technical documentation for project files and approvals
- Assistance during design, tendering, and construction phases
Why Intumescent Coatings Matter
Intumescent coatings are not simply decorative paints. They are engineered fire protection systems that must be selected and applied according to the structural design requirements, fire resistance criteria, and the characteristics of each steel member.
When exposed to fire, the coating expands and forms an insulating char layer that delays the temperature rise of the steel, helping maintain the structural integrity of the building.
Typical Applications
- Steel-framed buildings
- Industrial facilities
- Warehouses and logistics centers
- Commercial buildings
- Hotels and hospitality projects
- Airports and transportation hubs
- Public and educational buildings
- Architectural exposed steel structures
Contact Us
Send us your structural drawings, steel schedules, or fire resistance requirements, and our technical team will provide a tailored passive fire protection solution for your project.
BAUFORM – Passive Fire Protection Solutions for Structural Steel Technical consulting, specification support, supply, and application of certified intumescent coating systems.